AmberAir Compact S-CX • HRU with counter flow heat exchanger

  • Non-residential
  • Counterflow
  • R-COVERY by SALDA
  • Horizontal/Vertical

Heat recovery unit with counterflow heat exchanger, either with or without battery (electrical post-heater, change-over water battery or change-over DX battery). The unit is available in various versions up to ca. 5.000 m³/h with horizontal connections or ca. 3.000 m³/h with vertical connections and this in left or right version. The device is EPB tested according to NBN EN 308.

Brand

  • R-COVERY by SALDA

Application

  • Ventilation for both residential and non-residential applications
  • For indoor mounting
  • Outside mounting only possible for horizontal versions (with optional roof)

Composition

  • Outer panel: aluzinc RAL7040 (corrosion class C4)
  • Inner panel: aluzinc (corrosion class C4)
  • 50mm insulation
  • Mineral wool insulation, fire class A1
  • Round connections: for up to and including model 1500
  • Rectangular connections: from model 2000
  • Motorized registers and flexible sleeves available as an OPTION
  • Possibility of built-in battery
    • Vertical units: electrical or hot water battery
    • Horizontal units: electrical post-heater, change-over water battery or change-over DX battery
  • 100% Automatic bypass
  • Modbus communication as a standard
  • Communication possible via MB-GATEWAY (OPTION) with Modbus/BACnet/TCP-IP (Web server or App)
  • Constant flow control as a standard
  • Constant pressure control or CO2 control available as an option (sensors not included)
  • Filter detection via pressure switch
  • Controller is not included

Fan

  • Direct driven direct current EC fan with backward inclined blades
  • Constant flow regulation

Exchanger

  • High efficiency counterflow heat exchanger in aluminium
  • Heat exchanger certified according Eurovent EN 13141-7

Filter

  • The AmberAir Compact S-CX is equipped with bag filters M5 - ISO 16890 ePM10 65% (extraction) / F7 - ISO 16890 ePM1 55% (supply)

Versions

Certification

  • Tested according to NBN EN 308: www.epbd.be
  • Tested according to EUROVENT classifications according to EN13053
    • Mechanical strength: D1
    • Airtightness class: L1
    • Thermal transfer class: T2
    • Thermal bridge factor: TB2
    • Filter leakage: F9

Mounting

  • Up to model 5000 is delivered in one part.
  • Units up to model 2000 consist of a single part.
  • All horizontal models from size 3000 can be dismantled into 4 parts on site
  • Vertical model 3000 can be dismantled into 3 parts on site

Accessories

  • Touch screen controller, type TS-AIR
  • Control valve, type AKH (up to model 1500) / RM-RBS (from model 2000)
  • Air outlet, type UT (up to model 1500) / OC-RBS (from model 2000)
  • Connection piece, type MDV/MTS (up to model 1500) / MS-RBS (from model 2000)
  • Roof for outdoor installation, type RF-SCX
  • Comfortbox CB-SCX (attachment with additional battery)
  • Replacement filter, type FS-SCX
  • CO2 sensor, type DOX/E or WOX/E(-D)
  • Connecting multiple 0-10V sensors MM6-24/D

Order example

AmberAir Compact S-CXH 1000L BE MCB

Explanation

S-CX = with counterflow heat exchanger

H = horizontal version

1000 = size

L = left version

BE = electrical post-heater

MCB = type of regulation

EPB values

 Q [m³/h]ŋ t,epb [%]Pelec,epb [W]
AmberAir Compact S-CXH 2000157881654
AmberAir Compact S-CXV 2000161580651

Q = Flow rate
ŋ t,epb = Thermal efficiency EPB
Pelec,epb = Total electric power EPB

Technical data

AmberAir Compact S-CX 1000  S-CXH 1000
NB/CO/DX
S-CXH 1000
BE
S-CXV 1000
NB/BC
S-CXV 1000
BE
Main power supply [50Hz/VAC]1 x 2303 x 4001 x 2303 x 400
Heating batteryAbsorbed power[kW]-3-3
EC fansSupply voltage[50Hz/VAC]1 x 2301 x 2301 x 2301 x 230
Extraction fanPower/current[kW/A]0,5/2,20,5/2,20,5/2,20,5/2,2
Extraction fanFan speed[rpm]3740374037403740
Supply fanPowder/current[kW/A]0,5/2,20,5/2,20,5/2,20,5/2,2
Supply fanFan speed[rpm]3740374037403740
Max. electric power/current [kW/A]1,09/4,94,09/9,241,09/4,94,09/9,24
Recommanded fuse [A]10161016
 
AmberAir Compact S-CX 1500  S-CXH 1500
NB/CO/DX
S-CXH 1500
BE
S-CXV 1500
NB/BC
S-CXV 1500
BE
Main power supply [50Hz/VAC]1 x 2303 x 4001 x 2303 x 400
Heating batteryAbsorbed power[kW]-4.5-4.5
EC fansSupply voltage[50Hz/VAC]1 x 2301 x 2301 x 2301 x 230
Extraction fanPower/current[kW/A]0,5/2,20,5/2,20,5/2,20,5/2,2
Extraction fanFan speed[rpm]2700270027002700
Supply fanPowder/current[kW/A]0,5/2,20,5/2,20,5/2,20,5/2,2
Supply fanFan speed[rpm]2700270027002700
Max. electric power/current [kW/A]1,09/4,95,59/11,41,09/4,95,59/11,4
Recommanded fuse [A]10161016
 
AmberAir Compact S-CX 2000  S-CXH 2000
NB/CO/DX
S-CXH
2000 BE
S-CXV 2000
NB/BC
S-CXV 2000
BE
Main power supply [50Hz/VAC]1 x 2303 x 4001 x 2303 x 400
Heating batteryAbsorbed power[kW]-9-9
EC fansSupply voltage[50Hz/VAC]1 x 2301 x 2301 x 2301 x 230
Extraction fanPower/current[kW/A]0,78/4,00,78/4,00,78/4,00,78/4,0
Extraction fanFan speed[rpm]3730373037303730
Supply fanPowder/current[kW/A]0,78/4,00,78/4,00,78/4,00,78/4,0
Supply fanFan speed[rpm]3730373037303730
Max. electric power/current [kW/A]1,65/8,510,7/17,51,65/8,510,7/17,5
Recommanded fuse [A]16251625
 
AmberAir Compact S-CX 3000  S-CXH 3000
NB/CO/DX
S-CXH 3000
BE
S-CXV 3000
NB/BC
S-CXV 3000
BE
Main power supply [50Hz/VAC]1 x 2303 x 4003 x 4003 x 400
Heating batteryAbsorbed power[kW]-12-12
EC fansSupply voltage[50Hz/VAC]1 x 2301 x 2303 x 4003 x 400
Extraction fanPower/current[kW/A]1,3/6,61,3/6,61,5/2,31,5/2,3
Extraction fanFan speed[rpm]3000300031003100
Supply fanPowder/current[kW/A]1,3/6,61,3/6,61,5/2,31,5/2,3
Supply fanFan speed[rpm]3000300031003100
Max. electric power/current [kW/A]2,69/13,714,7/23,93,09/5,115,1/22,4
Recommanded fuse [A]20321032
       
AmberAir Compact S-CX 4000  S-CXH 4000
NB
S-CXH 4000
BE
S-CXH 4000
CO
S-CXH 4000
DX
Main power supply [50Hz/VAC]3 x 4003 x 4003 x 4003 x 400
Heating batteryAbsorbed power[kW]-18--
EC fansSupply voltage[50Hz/VAC]3 x 4003 x 4003 x 4003 x 400
Extraction fanPower/current[kW/A]2,5/4,02,5/4,02,5/4,02,5/4,0
Extraction fanFan speed[rpm]3100310031003100
Supply fanPowder/current[kW/A]2,5/4,02,5/4,02,5/4,02,5/4,0
Supply fanFan speed[rpm]3100310031003100
Max. electric power/current [kW/A]5,09/8,523,1/34,55,09/8,55,09/8,5
Recommanded fuse [A]12401212
       
AmberAir Compact S-CX 5000  S-CXH 5000
NB
S-CXH 5000
BE
S-CXH 5000
CO
S-CXH 5000
DX
Main power supply [50Hz/VAC]3 x 4003 x 4003 x 4003 x 400
Heating batteryAbsorbed power[kW]-21--
EC fansSupply voltage[50Hz/VAC]3 x 4003 x 4003 x 4003 x 400
Extraction fanPower/current[kW/A]2,5/4,02,5/4,02,5/4,02,5/4,0
Extraction fanFan speed[rpm]3100310031003100
Supply fanPowder/current[kW/A]2,5/4,02,5/4,02,5/4,02,5/4,0
Supply fanFan speed[rpm]3100310031003100
Max. electric power/current [kW/A]5,09/8,526,1/38,85,09/8,55,09/8,5
Recommanded fuse [A]12501212

Configuration horizontal

Configurations vertical

ETA = Air extraction
EHA = Air exhaust
SUP = Air supply
ODA = Fresh air intake

Dimensions

 Dimensions casing*Duct connectionsWeight
L [mm]W [mm]H [mm]ØD [mm]D [mm]G [mm][kg]
S-CXH 1000 NB/BE17657601039315--183/187
S-CXH 1000 CO/DX18457601039315--241/192
S-CXV 1000 NB/BE/BC13507551290315--217/221/228
S-CXH 1500 NB/BE23007981284400--258/263
S-CXH 1500 CO/DX23757981284400--271/269
S-CXV 1500 NB/BE/BC20007971690400--341/346/357
S-CXH 2000 NB/BE/CO/DX23758901285-500400359/364/373/370
S-CXV 2000 NB/BE/BC21468901655-300600420/424/434
S-CXH 3000 NB/BE/CO/DX270011001455-700400538/548/559/555
S-CXV 3000 NB/BE/BC243211001805-400700552/564/568
S-CXH 4000 NB/BE/CO/DX270013501505-1000500620/634/642/639
S-CXH 5000 NB/BE/CO/DX276016001505-1000500678/698/709/704
*Dimensional drawing: see "Downloads"