| Main power supply | | [50Hz/VAC] | 1 x 230 | 1 x 230 | 1 x 230 | 1 x 230 | | Heating battery | Absorbed power | [kW] | 4 | - | 4 | - | | EC Fans | Supply voltage | [50Hz/VAC] | 1 x 230 | 1 x 230 | 1 x 230 | 1 x 230 | | Extract fan | Power/current | [kW/A] | 0,33/1,55 | 0,33/1,55 | 0,33/1,55 | 0,33/1,55 | | Extract fan | Fan speed | [rpm] | 3350 | 3350 | 3350 | 3350 | | Supply fan | Power/current | [kW/A] | 0,33/1,55 | 0,33/1,55 | 0,33/1,55 | 0,33/1,55 | | Supply fan | Fan speed | [rpm] | 3350 | 3350 | 3350 | 3350 | | Max. electrical power/current | | [kW/A] | 4,75/10,0 | 0,75/3,5 | 4,75/10,0 | 0,75/3,5 | | Working temperature between -23°C and +40°C | |
| Main power supply | | [50Hz/VAC] | 1 x 230 | 1 x 230 | 1 x 230 | 1 x 230 | | Heating battery | Absorbed power | [kW] | 9 | - | 9 | - | | EC Fans | Supply voltage | [50Hz/VAC] | 1 x 230 | 1 x 230 | 1 x 230 | 1 x 230 | | Extract fan | Power/current | [kW/A] | 0,78/4,0 | 0,78/4,0 | 0,78/4,0 | 0,78/4,0 | | Extract fan | Fan speed | [rpm] | 3730 | 3730 | 3730 | 3730 | | Supply fan | Power/current | [kW/A] | 0,78/4,0 | 0,78/4,0 | 0,78/4,0 | 0,78/4,0 | | Supply fan | Fan speed | [rpm] | 3730 | 3730 | 3730 | 3730 | | Max. electrical power/current | | [kW/A] | 10,65/21,5 | 1,65/8,4 | 10,65/21,4 | 1,65/8,4 | | Working temperature between -23°C and +40°C |
Dimensions
|
|
| RIRS 1200 H | 1350 | 800 | 980 | 315 | 155 | | RIRS 1200 V | 1450 | 800 | 1090 | 315 | 168 | | RIRS 1900 H | 1500 | 850 | 1040 | 355 | 187 | | RIRS 1900 V | 1600 | 850 | 1140 | 355 | 190 | | *Dimensional drawing: see "Downloads" |
|