CAPACITY ACCORDING TO NEN-EN 14511 BRINE/WATER | | Soil/Water (vertical or horizontal collector) |
Rated heating capacity (B0/W35) | kW | 4.5 |
COP (B0/W35) | | 4.7 |
Rated heating capacity (B0/W55) | kW | 6 |
COP (B0/W55) | | 2.9 |
Maximum heating capacity (B0/W35) | kW | 9.1 |
COP (B0/W35) | | 4.5 |
Maximum heating capacity (B0/W55) | kW | 9 |
COP (B0/W55) | | 3 |
Cooling capacity (Passive) | kW | 3-9 |
SEASONAL HEATING CAPACITIES ACCORDING TO NEN-EN 14825 | | Average climate zone |
Rated heating capacity Pdesignh 35°C/55°C (B0) | kW | 9.1/9.0 |
35°C/55°C with source fluid at 0°C | SCOP | 5.45/4.04 |
CAPACITIES ACCORDING TO NEN-EN 14511 WATER/WATER | | Soil/Water (vertical or horizontal collector) |
Rated heating capacity (B10/W35) | kW | 4.5 |
COP (B10/W35) | | 6.4 |
Rated heating capacity (B10/W55) | kW | 6.1 |
COP (B10/W55) | | 3.8 |
Maximum heating capacity (B10/W35) | kW | 9.1 |
COP (B10/W35) | | 6.4 |
Maximum heating capacity (B10/W55) | kW | 9.1 |
COP (B10/W55) | | 3.8 |
Cooling capacity (Passive) | kW | 3-9 |
SEASONAL HEATING CAPACITIES ACCORDING TO NEN-EN 14825 | | Average climate zone |
Rated heating capacity Pdesignh 35°C/55°C (B10) | kW | 9.1/9.1 |
35°C/55°C with source fluid at 10°C | SCOP | 7.68/5.37 |
Refrigerant | | R-452B |
GWP | | 676 |
Amount of refrigerant | kg | 1.1 |
Hydraulic | | |
Primary side (heating source) - BRINE-WATER | | BUILT-IN CIRCULATION PUMP (PWM) |
Rated flow rate (min.-max.)* | m³/h | 1.4-2.15 |
Max. available external pressure** | kPa | 43.6 |
Brine pressure (min.-max.) | bar | 0.5-3.0 |
Secundary side (heat emitter) - WATER | | BUILT-IN CIRCULATION PUMP (PWM) |
Rated flow rate (min.-max.)* | m³/h | 0.8-1.55 |
Max. available external pressure** | kPa | 47.1 |
Primary side (heat source) - WATER-WATER | | BUILT-IN CIRCULATION PUMP (PWM) |
Rated flow rate (min.-max.)* | m³/h | 1.4-2.15 |
Min. pressure drop with MODUL_PIL ETERA*** | kPa | 18.7 |
Brine pressure (min.-max.) | bar | 0.5-3.0 |
Secundary side (heat emitter) - WATER | | BUILT-IN CIRCULATION PUMP (PWM) |
Rated flow rate (min.-max.)* | m³/h | 0.8-1.55 |
Max. available external pressure** | kPa | 47.1 |
Hot water heater 200 L in stainless steel for flush mounting/stand alone water heater | | HYDRO B/HYDRO BA |
Volume optional buffer tank** | l | 40 |
Heat loss Qst at 55°C | kwh/24h | 1.2 |
Heat loss Qst at 35°C | kwh/24h | 0.335 |
Operating range in heating | | |
-Min./max. temperature of fluid at source side | °C | -10/15 |
Operating range in cooling | | |
-Min./max. temperature of fluid at source side | °C | 5/25 |
Power supply | V | 230V 1 50 Hz |
Dimensions (L x H x D) ETERA (NET) | mm | 600x1515x600 |
Weight ETERA (NET) | kg | 189 |
Dimensions (L x H x D) ETERA (TRANSPORT) | mm | 700x1655x625 |
Weight ETERA (TRANSPORT) | kg | 200.5 |
VERSIONS | | |
Heat source | | Geothermal energy (Collector/ground water) |
Heat emitter | | Water |
Regulation | | KSM |
Warmtepomp locatie | | Indoor |
Position of regulation | | Built-in in heat pump unit |
Compressor | | 1 Scroll with variable speed |
Compressor driver | | DC Inverter |
Expansion valve | | Elektronical (EEV) |
Circulation pump on source side | | Built-in PWM |
Circulation pump on secundary side | | Built-in PWM |
Electrical heater | | 1 x 2 kW** |
3-way valve for switching from CV to DHW | | Built-in |
Water fow meter on heating side | | Built-in |
Flow switch on source side | | Built-in |
Water pressure sensor on heating side | | Built-in |
Water pressure sensor on source side | | Built-in |
Safety valve/pressure valve on heating side | | Built-in |
Safety valve/pressure valve on source side | | Built-in |
Expansion vessel 18 L on heating side | | Built-in |
Expansion vessel 18 L on source side | | Built-in |
Magnetic dirt separator/mechanical filter on heating side | | Built-in |
COMMUNICATION | | |
BMS connection | | MODBUS protocol (UTP cable with RJ45 connection) RS 485 |
Internet connection | | FTP cable - RJ45 connection - Ethernet |