PRODUCTS
EShop-number
Password
Welcome to CAIROX BELGIUM

R4LO HYDRO3 • Inverter Outdoor Units 3 Rooms Multi-split + DHW R-4LIVING

  • R-4LIVING
  • Multi-split
  • Outdoor unit
  • 10,6 - 11 kW
  • R32

This DC inverter multi-split system combines high efficiency with energy-saving operation. Thanks to the outdoor unit and a maximum piping length of up to 80 m (40 m of which is pre-charged), installation is extremely flexible, even in complex situations.
With a single system, you can cool or heat up to three rooms. Moreover, the unit simultaneously provides domestic hot water (DHW). In summer, it intelligently utilizes the "free" heat extracted from the cooled rooms, a sustainable solution that perfectly combines comfort and savings.

Brand

  • R-4LIVING

Product

  • 3-room multi-split + DHW outdoor unit

Application

  • Air-air heat pump, inverter

Function

  • Heat pump, inverter

Refrigerant

  • R32

Features

  • Multi-split air-to-air system with simultaneous domestic hot water production
  • High-efficiency DC inverter multi-system
  • DC rotary compressor
  • Fan with DC motor
  • Easy installation and maintenance
  • Flexible installation, total pipe length of 80m
  • Pre-charged for 40m
  • Outdoor temperature range in cooling mode: -15~+43°C
  • Outdoor temperature range in heating mode: -22~24°C

Accessories

  • 185L DHW tank. Type SHPB 185 HYDRO
  • SHPB DHW thermostat. Type TS-HYDRO
  • Painted wall bracket. Type WBA/WBC-HD
  • Stainless steel wall bracket. Type WBI
  • Rubber mounting blocks (15 cm). Type MPRH
  • Insulated copper pipes on a coil. Type P-COIL

Combination opportunities

ModelType of unitR4LO 36 HYDRO3
Basic wall modelsR4LW 09 VIVAx
R4LW 12 VIVAx
R4LW 18 VIVAx
R4LW 24 VIVAx
Design wall modelsR4LW 09 ONYXx
R4LW 12 ONYXx
R4LW 18 ONYXx
R4LW 24 ONYXx
Floor modelsR4LF 09 TERRAx
R4LF 12 TERRAx
R4LF 18 TERRAx

Specifications

Technical specifications R4LO 36 HYDRO3
Data according to standard combination 9+9+9+SWW
Cooling capacity (min. - nom. - max.)**kW2.6 - 10.6 - 12.0
Heating capacity (min. - nom. - max.)**kW3.0 - 12.0 - 14.0
(Max.) heating capacity at -7°C (outdoor @ 20°C (indoor)kW8.2
Absorbed power (rated) (C/H)kW3.0/3.2
EER (Cooling) 3.66
COP (Heating) 3.75
Pdesign (C/H)***kW10.6/10.5
SEER (Cooling) 7.2
SCOP (Heating) 4.2
Energy class (C/H) A++/A+
Absorbed current (rated) (C/H)A13.0/14.0
Annual energy consumption (C/H)kWh/j515/3500
Sound pressure leveldB(A)60
Sound power leveldB(A)70
Air flow rate (maximum)m³/h5800
Dimensions (H x W x D)mm826x1020x427
Weightkg72
Compressor inverter type DC Twin Rotary
Cooling pipesinch4x 1/4 - 3/8
Maximum length/height of cooling pipesm/m80/15
Maximum length of cooling pipes per indoor unitm20
Minimum length of cooling pipes per indoor unitm3
Refrigerant R32 (675)
Amount of pre-charged refrigerantg (CO2eq-T)2400 (1.62)
Number of prefilled metersm40
Extra amount of refrigerant per meterg/m20
Operating temperature in cooling mode°C-15~+43
Operating temperature in heating mode°C-22~+24
Power supplyV230/1
Power supply cable sectionmm²3G 6
Automatic fuse (slow)A32
* Specifications and design are subject to change for further improvement without prior notice.
** Cooling and heating capacities are achieved under the following conditions:
(Cooling) Indoor temp.: 27°C D.B./19°C W.B. - Outdoor temp.: 35°C D.B./24°C W.B.
(Heating) Indoor temp.: 20°C D.B. - Outdoor temp.: 7°C D.B./6°C W.B.
*** Pdesign is the cooling and heating capacity at the design temperature 35°C (C) and for the average climate zone at -10°C (H)
COP/EER according to EN14511 - SCOP/SEER according to EN14825 - sound power according to EN12102
Refrigeration adapter pieces supplied with outdoor unit

Combination tables

R4LO 36 HYDRO3 (min.18 kBtu - max.54 kBtu) - in COOLING*
 Indoor unit/RoomkBtuCooling capacityTotal cooling capacityAbsorbed powerSEEREnergy class
UnitUnitUnitUnitTot.UnitUnitUnitUnitnom (min - max)nom (min - max)
2 rooms99--182.62.6--5.2 (2.4 - 5.8)2.4 (1.6 - 3.5)7.2A++
912--212.63.5--6.1 (2.4 - 6.8)2.4 (1.6 - 3.5)7.2A++
918--272.65.0--7.6 (2.4 - 8.4)2.4 (1.6 - 3.5)7.2A++
924--332.67.2--9.8 (2.4 - 10.9)2.6 (1.6 - 3.6)7.2A++
1212--243.53.5--7.0 (2.4 - 7.8)2.4 (1.6 - 3.5)7.2A++
1218--303.55.0--8.5 (2.4 - 9.4)2.4 (1.6 - 3.5)7.2A++
1224--363.55.0--10.6 (2.4 - 12.0)3.0 (1.6 - 4.0)7.2A++
1818--365.35.3--10.6 (2.4 - 12.0)3.0 (1.6 - 4.0)7.2A++
1824--424.56.0--10.6 (2.4 - 12.0)3.0 (1.6 - 4.0)7.2A++
2424--485.35.3--10.6 (2.4 - 12.0)3.0 (1.6 - 4.0)7.2A++
3 rooms999-272.62.62.6-7.8 (2.4 - 8.6)2.4 (1.6 - 3.5)7.2A++
9912-302.62.64.2-9.4 (2.4 - 10.4)2.6 (1.6 - 3.6)7.2A++
9918-362.62.65.3-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
9924-422.32.36.0-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
91212-332.63.53.5-9.6 (2.4 - 10.6)3.0 (1.6 - 4.6)7.2A++
91218-392.43.24.9-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
91224-452.12.85.6-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
91818-452.14.24.2-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
91824-511.93.74.9-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
121212-363.53.53.5-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
121218-423.03.04.5-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
121224-482.62.65.3-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
121818-482.63.93.9-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
121824-542.33.54.7-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
181818-543.53.53.5-10.6 (2.4 - 12.0)3.0 (1.6 - 4.6)7.2A++
R4LO 36 HYDRO3 (min.18 kBtu - max.54 kBtu) - in HEATING*
 Indoor unit/RoomkBtuHeating capacityTotal heating capacityAbsorbed powerSCOPEnergy class
UnitUnitUnitUnitTot.UnitUnitUnitUnitnom (min - max)nom (min - max)
2 rooms99--182.82.8--5.6 (3.0 - 14.0)2.2 (1.6 - 3.1)4.0A+
912--212.83.8--6.6 (3.0 - 14.0)2.2 (1.6 - 3.1)4.0A+
918--272.85.6--8.4 (3.0 - 14.0)2.2 (1.6 - 3.6)4.0A+
924--332.88.5--11.3 (3.0 - 14.0)2.8 (1.6 - 5.0)4.0A+
1212--243.83.8--7.6 (3.0 - 14.0)2.2 (1.6 - 3.1)4.0A+
1218--303.85.6--9.4 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
1224--363.88.2--12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
1818--366.06.0--12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
1824--425.16.9--12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
2424--486.06.0--12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
3 rooms999-272.82.82.8-8.4 (3.0 - 14.0)2.2 (1.6 - 3.6)4.0A+
9912-302.82.83.8-9.4 (3.0 -14.0)2.8 (1.6 - 5.0)4.0A+
9918-363.03.06.0-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
9924-422.62.66.9-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
91212-333.24.44.4-11.3 (3.0 - 14.0)2.8 (1.6 - 5.0)4.0A+
91218-392.83.75.5-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
91224-452.43.26.4-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
91818-452.44.84.8-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
91824-512.14.25.7-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
121212-364.04.04.0-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
121218-423.43.45.1-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
121224-483.03.06.0-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
121818-483.04.54.5-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
121824-542.74.05.3-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
181818-544.04.04.0-12.0 (3.0 - 14.0)3.1 (1.6 - 5.0)4.0A+
Combinations of indoor units shown here are models of working units, not of connectable units.
A minimum of 2 indoor units must be connected with a total of 18 kBtu.
A maximum of 4 indoor units can be connected with a total of 54 kBtu.
* Cooling and heating capacities are achieved under the following conditions:
(Cooling) Indoor temp.: 27°C D.B./19°C W.B. - Outdoor temp.: 35°C D.B./24°C W.B.
(Heating) Indoor temp.: 20°C D.B. - Outdoor temp.: 7°C D.B./6°C W.B.
SCOP/SEER according to EN14825
HELPCopyrightSales conditionsCookie policyAirvance Group

Requesting information. Please wait a moment...